Steam, Its Generation and UseBabcock & Wilcox Company
History
Steam, Its Generation and Use
Babcock & Wilcox Company
Steam-boilers, Water-tube
The gas passages are ample and are so proportioned that the resistance
offered to the gases is only such as will assure the proper abstraction
of heat from the gases without causing undue friction, requiring
excessive draft.
[Illustration: Partial Vertical Section Showing Method of Introducing
Feed Water]
The method in which the feed water is introduced through the front
drumhead of the boiler is clearly seen by reference to the illustration.
From this point of introduction the water passes to the rear of the
drum, downward through the rear circulating tubes to the sections,
upward through the tubes of the sections to the front headers and
through these headers and front circulating tubes again to the drum
where such water as has not been formed into steam retraces its course.
The steam formed in the passage through the tubes is liberated as the
water reaches the front of the drum. The steam so formed is stored in
the steam space above the water line, from which it is drawn through a
so-called "dry pipe." The dry pipe in the Babcock & Wilcox boiler is
misnamed, as in reality it fulfills none of the functions ordinarily
attributed to such a device. This function is usually to restrict the
flow of steam from a boiler with a view to avoid priming. In the Babcock
& Wilcox boiler its function is simply that of a collecting pipe, and as
the aggregate area of the holes in it is greatly in excess of the area
of the steam outlet from the drum, it is plain that there can be no
restriction through this collecting pipe. It extends nearly the length
of the drum, and draws steam evenly from the whole length of the steam
space.
[Illustration: Cast-iron Vertical Header Longitudinal Drum Babcock &
Wilcox Boiler]
[Illustration:
Closed Open
Patented Side Dusting Doors]
The large tube doors through which access is had to the front headers
and the doors giving such access to the rear headers in boilers of the
vertical header type have already been described and are shown clearly
by the illustrations on pages 56 and 74. In boilers of the inclined
header type, access to the rear headers is secured through the chamber
formed by the headers and the rear boiler wall. Large doors in the sides
of the setting give full access to all parts for inspection and for
removal of accumulations of soot. Small dusting doors are supplied for
the side walls through which all of the heating surfaces may be cleaned
by means of a steam dusting lance. These side dusting doors are a
patented feature and the shutters are self closing. In wide boilers
additional cleaning doors are supplied at the top of the setting to
insure ease in reaching all portions of the heating surface.