THE COMMON WELFARE
=THE BINGHAMTON FIRE AND ENCLOSED STAIRWAYS=
After many conferences and two days of public hearings on the enclosure
of factory stairways, following the Binghamton fire--and backed by the
attorney-general’s opinion in regard to the scope of its powers--the
industrial board of the New York Department of Labor has adopted rules
and regulations for the enclosure of stairways in factories of four
stories or under. On account of the vital importance of exits, their
rules are quoted in full:
Regulation No. 1. In all factory buildings less than
five stories in height in which more than twenty-five
persons are employed above the ground floor, or in which,
regardless of the number of persons employed, articles,
goods, wares, merchandise or products of combustible
material are stored, packed, manufactured or in the
process of manufacture, all interior stairways serving as
required means of exit, and the landings, platforms, and
passageways connected therewith, shall be enclosed on all
sides by partitions of fire-resisting material extending
continuously from the basement. Where the stairway extends
to the top floor of the building such partitions shall
extend to three feet above the roof. All openings in such
partitions shall be provided with self-closing doors
constructed of fire-resisting material, except where such
openings are in the exterior wall of the building. The
bottom of the enclosure shall be of fireproof material
at least four inches thick, unless the fire-resisting
partitions extend to the cellar bottom.
Such enclosure of stairways shall not be required in
factory buildings in which there is an exterior enclosed
fireproof stairway or a horizontal exit serving as a
required means of exit, as defined in Section 79f,
Subdivisions 8 and 9 of the labor law. Where approved
automatic sprinklers are installed throughout such
buildings, such enclosure of stairways shall not be
required unless more than eighty persons are employed above
the ground floor.
Regulation No. 2. In all factory buildings no articles
or wares of a combustible nature shall be kept or stored
inside the limits of any stairway enclosure, or unenclosed
stairway, or on the landings, platforms, or passageways
connected therewith, nor shall such articles or wares be
kept or stored under any stairway unless such stairway and
any partitions or doors thereunder are constructed of, or
covered with, incombustible material.
Both rules become effective October 1, 1913. The labor law specifically
provides for the enclosure of stairways in buildings over four stories.