Tomato products: pulp, ketchup, and chili sauce. — John Shaqi
Tomato products: pulp, ketchup, and chili sauce.Bigelow, W. D. (Willard Dell)
Science
Tomato products: pulp, ketchup, and chili sauce.
Bigelow, W. D. (Willard Dell)
Tomato products
[3] Tomatoes are sometimes found with rotten centers of which there
is little or no external evidence. This is unusual, however, and
the influence of this form of rot under manufacturing conditions is
negligible.
The Bureau of Chemistry condemns tomato pulp whose microscopic
examination gives results as high as the following figures:
Molds 66 per cent of fields.
Bacteria 100 million per cubic centimeter.
Yeasts and spores 125 per 1/60 cubic millimeter.
These figures, of course, apply to the Howard method as employed by
the Bureau of Chemistry. The method is entirely arbitrary and results
agreeing with those obtained by the Bureau of Chemistry can be obtained
only by using this method substantially as it is used by the bureau.
An examination of the pulp, therefore, by an analyst who is not
thoroughly conversant with this method as it is employed by the Bureau
of Chemistry not only is useless but may actually afford a manufacturer
a false sense of security which will be greatly to his disadvantage.
Microscopic Equipment Required
The apparatus employed by the Bureau of Chemistry includes apochromatic
objectives and compensating oculars. In 1914 it became impossible to
obtain these accessories[4] because of the European war and equivalent
apparatus of American manufacture was found to give the same results.
Both of these forms of apparatus are recognized in the official Howard
method which is given below.
[4] Apochromatic objectives may now be obtained but are more expensive
than the achromatic.
This laboratory made a careful study of the accessories available in
order to determine what could best be used. It was found that very
satisfactory results could be obtained by employing a 10X Huyghenian
ocular and a 4 mm. achromatic objective (working distance 0.6 mm.) and
a 16 mm. achromatic objective. These accessories require a careful
adjustment of light, but with proper use enable an analyst to secure
satisfactory results. It is found that the best results are obtained
with a rather dark field.
The apparatus necessary for the Howard method, including the
accessories mentioned above, may be obtained of two American
manufacturers, the Bausch & Lomb Optical Company, of Rochester, N. Y.,
and the Spencer Lens Company, of Buffalo, N. Y.
There is given below a full list of the optical apparatus required,
including catalog numbers of the two manufacturers, as far as numbers
have been assigned by them to the various items. In addition to the
apparatus given in this list, the analyst should have a 50 c. c.
graduated cylinder for measuring and diluting samples. This may be
obtained of any dealer in chemical apparatus and at many drug stores.
When ordering the optical apparatus the full description as given below
should be included.
Optical Apparatus for the Howard Method
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account