As instances of the way in which the character of the strata may
influence the water-bearing capacity of any given locality, we give the
following examples, taken from Baldwin Latham's papers on 'The Supply of
Water to Towns.' Fig. 1 illustrates the causes which sometimes conduce
to a limited supply of water in Artesian wells. Rain descending on the
outcrop E F of the porous stratum A, which lies between the impervious
stratum B B, will make its appearance in the form of a spring at S; but
such spring will not yield any great quantity of water, as the area E F,
which receives the rainfall, is limited in its extent. A well sunk at W,
in a stratum of the above description, would not be likely to furnish a
large supply of water, if any. The effect of a fault is shown in Fig. 2.
A spring will in all probability make its appearance at the point S, and
give large quantities of water, as the whole body of water flowing
through the porous strata A is intercepted by being thrown against the
impermeable stratum B. Permeable rock intersected by a dyke and
overlying an impermeable stratum is seen in Fig. 3. The water flowing
through A, if intersected by a dyke D, will appear at S in the form of a
spring, and if the area of A is of large extent, then the spring S will
be very copious. As to the depth necessary to bore certain wells, in a
case similar to Fig. 4, owing to the fault, a well sunk at A would
require to be sunk deeper than the well B, although both wells derive
their supply from the same description of strata. If there is any
inclination in the water-bearing strata, or if there is a current of
water only in one direction, then one of the wells would prove a failure
owing to the proximity of the fault, while the other would furnish an
abundant supply of water.
[Illustration: Permeable Rock Intersected by a Dyke.
Fig. 3.]
It should be borne in mind that there are two primary geological
conditions upon which the quantity of water that may be supplied to the
water-bearing strata depends; they are, the extent of superficial area
presented by these deposits, by which the quantity of rain-water
received on their surface in any given time is determined; and the
character and thickness of the strata, as by this the proportion of
water that can be absorbed, and the quantity which the whole volume of
the permeable strata can transmit, is regulated. The operation of these
general principles will constantly vary in accordance with local
phenomena, all of which must, in each separate case, be taken into
consideration.
[Illustration: Well Depth either side of a Fault.
Fig. 4.]
Public-domain text, read in full here on John Shaqi.