11. The lines of railway leading to the passenger platforms to be
arranged so that the engines shall always be in front of the passenger
trains as they arrive at and depart from a station; and so that, in
the case of double lines, or of passing places on single lines, each
line shall have its own platform. At terminal stations a double line
of railway must not end as a single line.
12. Platforms to be continuous, and not less than 6 feet wide for
stations of small traffic, nor less than 12 feet wide for important
stations. The descents at the ends of the platforms to be by ramps,
and not by steps. Pillars for the support of roofs and other fixed
works not to be less than 6 feet from the edges of the platforms. The
height of the platforms above rail level to be 3 feet, save under
exceptional circumstances, and in no case less than 2 feet 6 inches.
The edges of the platforms to overhang not less than 12 inches. As
little space as possible to be left between the edges of the platforms
and those of the footboards on the carriages. Shelter to be provided
on every platform, and conveniences where necessary. Names of stations
to be shown on boards and on the platform lamps.
13. When stations are placed on, or near a viaduct, or bridge under
the railway, a parapet or fence on each side to be provided of
sufficient height to prevent passengers, who may by mistake leave the
carriages when not at the platform, from falling from the viaduct or
bridge in the dark.
[Illustration: Fig. 11.]
14. Footbridges or subways to be provided for passengers to cross the 26
railway at all exchange and other important stations. Staircases or
ramps leading to or from platforms to be at no point narrower than at
the top, and the available width to be in no case contracted by any
erection or fixed obstruction whatever below the top.
At all stations where crowding may be expected, the staircases or
ramps to be of ample width, and barriers for regulating the entrance
of the crowd at the top to be erected. If in such cases there are
gates at the bottom, a speaking-tube or other means of communication
between the top and bottom to be provided; and in all cases gates at
the bottom of a staircase or ramp to open outwards. For closing the
openings at the top, sliding bars or gates are considered best.
The steps of staircases to be never less than 11 inches in the tread,
nor more than 7 inches in the rise, and midway landings to be provided
where the height exceeds 10 feet.
Efficient handrails to be provided on both staircases and ramps, and
in subways where ramps are used the inclination not to exceed 1 in 8.
15. A clock to be provided at every station, in some conspicuous
position visible from the platforms.