If the end-point is determined as prescribed, it can be as accurately
fixed as that of other methods; and if a ferrous solution is at
hand, the titration need consume hardly more time than that of the
permanganate process to be described later on.]
STANDARDIZATION OF POTASSIUM BICHROMATE SOLUTIONS
!Selection of a Standard!
A substance which will serve satisfactorily as a standard for
oxidizing solutions must possess certain specific properties: It must
be of accurately known composition and definite in its behavior as a
reducing agent, and it must be permanent against oxidation in the air,
at least for considerable periods. Such standards may take the form of
pure crystalline salts, such as ferrous ammonium sulphate, or may be
in the form of iron wire or an iron ore of known iron content. It is
not necessary that the standard should be of 100 per cent purity,
provided the content of the active reducing agent is known and no
interfering substances are present.
The two substances most commonly used as standards for a bichromate
solution are ferrous ammonium sulphate and iron wire. A standard wire
is to be purchased in the market which answers the purpose well, and
its iron content may be determined for each lot purchased by a number
of gravimetric determinations. It may best be preserved in jars
containing calcium chloride, but this must not be allowed to come
into contact with the wire. It should, however, even then be examined
carefully for rust before use.
If pure ferrous ammonium sulphate is used as the standard, clear
crystals only should be selected. It is perhaps even better to
determine by gravimetric methods once for all the iron content of a
large commercial sample which has been ground and well mixed. This
salt is permanent over long periods if kept in stoppered containers.
STANDARDIZATION
PROCEDURE.--Weigh out two portions of iron wire of about 0.24-0.26
gram each, examining the wire carefully for rust. It should be handled
and wiped with filter paper (not touched by the fingers), should
be weighed on a watch-glass, and be bent in such a way as not to
interfere with the movement of the balance.